Antoine equation

Source: Wikipedia, the free encyclopedia.

The Antoine equation is a class of

semi-empirical correlations describing the relation between vapor pressure and temperature for pure substances. The Antoine equation is derived from the Clausius–Clapeyron relation. The equation was presented in 1888 by the French engineer Louis Charles Antoine [fr] (1825–1897).[1]

Equation

The Antoine equation is

where p is the vapor pressure, T is temperature (in °C or in K according to the value of C) and A, B and C are component-specific constants.

The simplified form with C set to zero:

is the August equation, after the German physicist

heat of vaporization
. The Antoine equation allows an improved, but still inexact description of the change of the heat of vaporization with the temperature.

The Antoine equation can also be transformed in a temperature-explicit form with simple algebraic manipulations:

Validity range

Usually, the Antoine equation cannot be used to describe the entire saturated vapour pressure curve from the

normal boiling point
and the second set of parameters is used for the range from the normal boiling point to the critical point.

  • Typical deviations of a parameter fit over the entire range (experimental data for Benzene)
  • Deviations of an August equation fit (2 parameters)
    Deviations of an August equation fit (2 parameters)
  • Deviations of an Antoine equation fit (3 parameters)
    Deviations of an Antoine equation fit (3 parameters)
  • Deviations of a DIPPR 105 equation fit (4 parameters)
    Deviations of a DIPPR 105 equation fit (4 parameters)

Example parameters

Parameterisation for T in °C and P in mmHg
A B C T min. (°C) T max. (°C)
Water 8.07131 1730.63 233.426 1 100
Water 8.14019 1810.94 244.485 99 374
Ethanol 8.20417 1642.89 230.300 −57 80
Ethanol 7.68117 1332.04 199.200 77 243

Example calculation

The normal boiling point of ethanol is TB = 78.32 °C.

(760 mmHg = 101.325 kPa = 1.000 atm = normal pressure)

This example shows a severe problem caused by using two different sets of coefficients. The described vapor pressure is not continuous—at the normal boiling point the two sets give different results. This causes severe problems for computational techniques which rely on a continuous vapor pressure curve.

Two solutions are possible: The first approach uses a single Antoine parameter set over a larger temperature range and accepts the increased deviation between calculated and real vapor pressures. A variant of this single set approach is using a special parameter set fitted for the examined temperature range. The second solution is switching to another vapor pressure equation with more than three parameters. Commonly used are simple extensions of the Antoine equation (see below) and the equations of DIPPR or Wagner.[2][3]

Units

The coefficients of Antoine's equation are normally given in mmHg—even today where the SI is recommended and pascals are preferred. The usage of the pre-SI units has only historic reasons and originates directly from Antoine's original publication.

It is however easy to convert the parameters to different pressure and temperature units. For switching from degrees Celsius to kelvin it is sufficient to subtract 273.15 from the C parameter. For switching from millimeters of mercury to pascals it is sufficient to add the common logarithm of the factor between both units to the A parameter:

The parameters for °C and mmHg for ethanol

  • A, 8.20417
  • B, 1642.89
  • C, 230.300

are converted for K and Pa to

  • A, 10.32907
  • B, 1642.89
  • C, −42.85

The first example calculation with TB = 351.47 K becomes

A similarly simple transformation can be used if the common logarithm should be exchanged by the natural logarithm. It is sufficient to multiply the A and B parameters by ln(10) = 2.302585.

The example calculation with the converted parameters (for K and Pa):

  • A, 23.7836
  • B, 3782.89
  • C, −42.85

becomes

(The small differences in the results are only caused by the used limited precision of the coefficients).

Extension of the Antoine equations

To overcome the limits of the Antoine equation some simple extension by additional terms are used:

The additional parameters increase the flexibility of the equation and allow the description of the entire vapor pressure curve. The extended equation forms can be reduced to the original form by setting the additional parameters D, E and F to 0.

A further difference is that the extended equations use the e as base for the exponential function and the natural logarithm. This doesn't affect the equation form.

Sources for Antoine equation parameters

See also

References

  1. Comptes Rendus des Séances de l'Académie des Sciences
    (in French), 107: 681–684, 778–780, 836–837

External links