Oligohydramnios

Source: Wikipedia, the free encyclopedia.
Oligohydramnios
SpecialtyObstetrics Edit this on Wikidata

Oligohydramnios is a medical condition in pregnancy characterized by a deficiency of amniotic fluid, the fluid that surrounds the fetus in the abdomen, in the amniotic sac. It is typically diagnosed by ultrasound when the amniotic fluid index (AFI) measures less than 5 cm or when the single deepest pocket (SDP) of amniotic fluid measures less than 2 cm.[1] Amniotic fluid is necessary to allow for normal fetal movement, lung development, and cushioning from uterine compression.[2] Low amniotic fluid can be attributed to a maternal, fetal, placental or idiopathic cause and can result in poor fetal outcomes including death. The prognosis of the fetus is dependent on the etiology, gestational age at diagnosis, and the severity of the oligohydramnios.

The opposite of oligohydramnios is polyhydramnios, or an excess of amniotic fluid.

Etiology

The amount of amniotic fluid available is based on how much fluid is produced and how much is removed from the amniotic sac. In the first trimester, the main sources of amniotic fluid are fetal lung secretions, transportation of maternal plasma across the fetal membranes, and the surface of the placenta. By the second trimester, the fetal kidneys start to produce urine which becomes the main source of the amniotic fluid for the remainder of the pregnancy.[3]

The development of oligohydramnios may be idiopathic or have a maternal, fetal, or placental cause.[4]

Maternal

Fetal

Placental

Diagnosis

Clinical Manifestation

The volume of amniotic fluid typically increases until 36 weeks and starts decreasing after 40 weeks in post-term gestations.[3] For this reason, discrepancies between fundal height measurements and gestational age can be a clinical indication of amniotic fluid abnormality and should be evaluated by ultrasound. Other common clinical presentations include fetal malpresentation, undue prominence of fetal parts, premature rupture of membranes, and reduced amount of amniotic fluid.[citation needed]

Diagnosis

Diagnosis of oligohydramnios is made by conducting a transabdominal ultrasound of the abdomen. There are two methods that can be used to make the diagnosis. The first is by using an amniotic fluid index (AFI). In this method, the sonographer measures the amniotic fluid in each of the four quadrants of the abdomen (right upper quadrant, left upper quadrant, right lower quadrant, left lower quadrant) and adds the values together. For reference, a normal AFI is 5–25 cm. An AFI <5 cm is considered oligohydramnios and an AFI >25 cm is considered polyhydramnios. Randomized control trials have shown that use of AFI can cause an increased number of false positive diagnosis of oligohydramnios and recommend using the measurement of a single deepest pocket (SDP) of amniotic fluid to diagnose oligohydramnios instead.[1]

To calculate a single deepest pocket, the sonographer scans each of the four quadrants of the abdomen looking for the deepest pocket of amniotic fluid that does not include any fetal body parts or an umbilical cord. It is measured from the 12 o'clock position to the 6 o'clock position. For reference, a normal SDP is 2–8 cm. A SDP <2 cm is considered oligohydramnios and a SDP >8 cm is considered polyhydramnios. The use of a SDP for diagnosis of oligohydramnios is associated with less false positives and thus less unnecessary interventions without an increase in adverse perinatal outcomes.[1]

In a multiple gestation pregnancy, measuring a single deepest pocket is the most accurate determination of adequate amniotic fluid levels.[2]

Management

After initial diagnosis of oligohydramnios has been made, the next step is to perform a thorough history and physical exam, followed by diagnostic testing if indicated.[2]

  • Retaking a maternal and family history and performing a physical exam can point to maternal conditions or medications that might be causing the oligohydramnios.
  • Premature prelabor rupture of membranes or prelabor rupture of membranes is ruled out with a nitrizine test, evidence of ferning, or evidence pooling of liquid in the cervix.
  • Sonographic evaluation of the fetus is done to identify fetal anomalies, aneuploidy, fetal growth restriction, or placental abnormalities. The National Institute of Health recommends detailed documentation of certain fetal organs that are most likely to be involved such as the kidneys, bladder, and the umbilical cord. If the lack of amniotic fluid prevents accurate visualization on ultraosund, MRI imaging can be considered. Genetic testing can be useful if fetal anomalies are documented on imaging.
  • An elevated maternal serum alpha fetal protein (MSAFP) can indicate leaking amniotic fluid due to damage to fetal membranes or the placenta. This is associated with a poor prognosis.
  • A maternal blood test or amniotic fluid test can be performed if suspicion of a TORCH infection is high.

Increasing amniotic fluid

There is no way to permanently increase the volume of amniotic fluid, but it can be temporarily increased to allow for a complete anatomy scan of the fetus on ultrasound.[citation needed]

One way to achieve this is through an

multidisciplinary team.[5]

One to two liters of oral hydration can temporarily increase amniotic fluid in dehydrated patients with isolated oligohydramnios.[6]

Other investigational therapies may also be useful such as desmopressin, tissue sealants, or sildenafil citrate. These methods are less commonly used and are experimental.[4]

In case of

randomized yet small study.[7]

Prenatal care

Patients who are preterm are managed in the outpatient setting with weekly or biweekly testing to monitor for accurate fetal growth and decrease chances of unexpected fetal death. This includes a weekly non-stress test (NST) and single deepest pocket (SDP) assessment which is also referred to as the modified BPP.[1] Sonographic fetal growth exams may also be indicated.[citation needed]

Timing of delivery

Idiopathic, uncomplicated, and persistent oligohydramnios can be delivered at 36 0/7 weeks – 37 6/7 weeks of gestation or at diagnosis if diagnosis is later.[1]

Complications

Complications may include cord compression, musculoskeletal abnormalities such as facial distortion and clubfoot, pulmonary hypoplasia and intrauterine growth restriction. Amnion nodosum is frequently also present (nodules on the fetal surface of the amnion).[8]

The use of oligohydramnios as a predictor of gestational complications is controversial.[9][10]

Potter syndrome
is a condition caused by oligohydramnios. Affected fetuses develop pulmonary hypoplasia, limb deformities, and characteristic facies. Bilateral agenesis of the fetal kidneys is the most common cause due to the lack of fetal urine.

See also

  • Fetal intervention
  • Potter's sequence

References

  1. ^ a b c d e "Antepartum Fetal Surveillance". www.acog.org. Retrieved 2021-11-07.
  2. ^ a b c d "UpToDate". www.uptodate.com. Retrieved 2021-11-07.
  3. ^
    PMID 32965997
    , retrieved 2021-11-07
  4. ^ a b "UpToDate". www.uptodate.com. Retrieved 2021-11-07.
  5. National Institute for Health and Clinical Excellence. Based on the overview Therapeutic amnioinfusion for oligohydramnios during pregnancy (excluding labour) Archived 2013-02-18 at the Wayback Machine
    in 2006
  6. .
  7. .
  8. .
  9. .
  10. .

External links