Tracer-gas leak testing
(Redirected from
Tracer gas
)A tracer-gas leak testing method is a
semiconductors
, among other uses.
Types
Several tracer-gas leak testing methods exist, including:
- Detection of leaks using helium mass spectrometer, which provides high sensitivity
- Hydrogen leak testing, which provides the best mobility
- Refrigerant gas leak detection, for refrigeration applications
Method selection
Typical leakage rates
The nature of the product or the process and the process gases will set the leak rate requirement:
System | Allowed leak rate ( mbar L /s)
|
---|---|
Chemical process equipment | 10−1–1 |
Beverage can | 10−5 –10−6 |
Vacuum pumped system | 10−5–10−7 |
IC-package | 10−7–10−8 |
Airbag cartridge | 10−8 |
Pacemaker | 10−9 |
Closed vacuum system | 10−9 |
Sensitivity of methods
Based on the target leak rate, the table below will help to choose the most suitable method.[2]
Method | Sensitivity (leak rate in mbar l/s) |
---|---|
Ultrasonics | 10−1 |
Bubble test in water | 10−2 |
Pressure decay | 10−2 |
Vacuum decay | 10−2 |
Acoustic emission detectors | 10−3 |
Bubble test in soapy water | 10−4 |
Gas-specific thermal conductivity detector
|
10−5 |
Halogen detector | 10−5 |
Photoacoustic spectroscopy | 10−6 |
Hydrogen sniffer | 10−6 |
Residual gas analyser
|
10−7 |
Dye penetrant | 10−8 |
Radioactive tracer | 10−10 |
Helium mass spectrometry vacuum testing | 10−11 |
Applications
Typical applications of tracer-gas leak testing include:
- In petrochemical plants, hydrocracking, vapocracking, catalytic reforming, and steam reforming are all hydrogen-based processes, in which were hydrogen leak testing is required.
- When manufacturing PECVD, PVD and ion implantation– require helium or hydrogen leak testing.
- In vehicles, air conditioningsystem, fuel system, and exhaust system require testing for leaks.
- Pacemakers and cathetershave to be tested for efficacy and longevity.
- On planes, tracer-gas leak testing is used to quickly and safely locate fuel leaks,[3] as well as to check oxygen distribution devices and cabin pressurization systems.
- Refrigeration and air conditioning must have the lowest possible rate of loss of refrigerant gases (contributing to ozone depletion).
- Sewage and drinking water networks, to reduce loss of water and make sure drinking water is not contaminated by sewage.
Standards
Several standards apply to leak testing and more specifically to tracer-gas leak testing methods, for example:
- BS EN 1779:1999; leak tightness by indication or measurement of gas leakage,
- BS EN 13185:2001 Non-destructive testing. Leak testing. Tracer gas method,
- BS EN 13192:2002 Non-destructive testing. Leak testing. Calibration of reference leaks for gases.
References
- ^ Batajtis, Damian. "Tracer Gas as a Method for Water Leak Detection" (PDF). Wizard Leak Detection. Archived (PDF) from the original on 12 November 2023. Retrieved 12 November 2023.
- ^ "Leak Detection Sensitivity Guide - VIC Leak Detection". VIC Leak Detection. Retrieved 2017-06-15.
- ISSN 0261-3077. Retrieved 2017-06-15.