Viral load monitoring for HIV

Source: Wikipedia, the free encyclopedia.

Viral load monitoring for HIV is the regular measurement of the

treatment of HIV/AIDS.[1]
A count of the viral load is routine before the start of HIV treatment.[1]

Types

Various viral load tests might be used. One way to classify tests is by whether it is a nucleic acid test or non-nucleic acid test.[2] Variation in cost and the time it takes to get a result may be factors in selecting the type of test used.[3]

Uses

Viral load monitoring is used by

treatment of HIV/AIDS.[1]

A count of the viral load is routine before the start of HIV treatment.[1] If the treatment is not changed, then viral load is monitored with testing every 3–4 months to confirm a stable low viral load.[1] Patients who are medically stable and who have low viral load for two years may get viral load counts every 6 months instead of 3.[1] If a viral load count is not stable or sufficiently low, then that might be a reason to modify the HIV treatment.[1] If HIV treatment is changed, then the viral load should be tested 2–8 weeks later.[1]

Typical interpretation of results

Previous treatment guidelines recommended that anyone with a viral load greater than 100,000 copies/mL of blood should begin treatment. It is now standard of care in the United States to begin anti-retroviral treatment upon discovery of HIV positive status. HIV is a

RNA genome. HIV also produces an integrase
enzyme which is used to integrate the newly produced viral DNA into the host's DNA. The virus is then replicated every time the host cell's DNA replicates. Due to the nature of the virus the drugs used to treat HIV are called antiretroviral medicines, and the course of treatment is called antiretroviral therapy (ART). These potent medicines cannot cure an individual; they can however manage the virus and slow the progression of the HIV infection. Strict compliance with the prescribed ART regimen is vital to controlling the disease.[citation needed]

Highly active antiretroviral therapy (HAART) is the current recommended treatment for HIV. HAART entails taking a combination (regimen) of three or more ART medications from at least two different classes of drugs. There are six classes of ART medications: [citation needed
]

Each class of medications uses a different mode of action to blocks the virus. Treatment is more effective in controlling the virus when a combination of medications from different classes is used. HAART also reduces the risk of developing drug resistance. Viral load tests are used to monitor the effects ART, to track viral suppression, and detect treatment failure. Successful combination ART should give a fall in viral load of 1.5 to 2 logs (30-100 fold) within six weeks, with the viral load falling below the limit of detection within four to six months.[4]

Laboratory monitoring schedule for patients using ART:

Initial Physician visit Prior to beginning ART Beginning or modifying ART 2 – 8 weeks after beginning or modifying ART Every 3 – 6 months Every 6 – 12 months Other
Viral load When entering into care Every 3 – 6 months Baseline for comparison Repeat every 4 – 8 weeks until viral load is suppressed to <200 copies/mL blood, then every 3 – 6 months Individuals with a suppressed viral load, who are clinically & immunologically stable for more than 2 – 3 years, may go to every 6 months Treatment failure or when clinically indicated
CD4 When entering into care Every 3 – 6 months Baseline for comparison Routine monitoring Individuals with a suppressed viral load, who are clinically stable, CD4 count monitoring may go to every 6 – 12 months Treatment failure or when clinically indicated

CD4 count indication

Viral load monitoring for HIV complements the CD4 count, which is another sort of test associated with monitoring HIV. Confusion about when to take a CD4 test is common.

opportunistic diseases.[citation needed
]

Blips in data

While receiving ART some patients with undetectable viral load measurements may experience an increase in viral load, to a low level (usually below 400 copies/mL blood), and then returned to an undetectable level. These transient blips do not indicate that the virus is developing resistance to drug therapy. Blips appear to be more common in the winter, suggesting a connection with illness such as colds and influenza.

viral mutations, and often dictate changes in ART.[citation needed
]

Special populations

The

HIV antibody test usually detects the HIV antibodies
within two to eight weeks, but can have a valid negative result for a long as 2 to 6 months after initial infection. Viral load tests can also be used to diagnose HIV infection, especially in children under 18 months born to mothers with HIV, where the presence of maternal antibodies prevents the use of antibody-based (
diagnostic tests.[8] Pooled viral RNA testing shortens the window period to a median of 17 days (95% CI, 13-28 Days).[9] Although it is not the standard of care to use this test for diagnosis, in communities with high HIV prevalence, this test has a significantly improved negative predictive value over 3rd and 4th generation tests for detecting acute HIV infections.[10][11]

Adverse effects

Safe sex practices are recommended for people with low viral load, just the same as for everyone else.[12] Researchers have questioned whether people who are told that they have a low viral load will respond to this information by lowering their use of safe sex practices.[12] As of 2010, further research might clarify the uncertainty around that idea.[12]

History

In January 2008, researchers from Switzerland published what would be termed the Swiss Statement, controversially arguing that HIV-positive individuals 1) on antiretroviral therapy, 2) with a viral load under 40 copies per mL, and 3) with no other sexually transmitted diseases themselves or in their partners could be assumed to not transmit the disease to healthy, HIV-negative partners.[13] Concerns were raised that blood-based measures of HIV viral concentrations at the time might not reflect actual viral counts in semen, and thus the Statement could encourage needlessly risky sexual practices, though the Statement authors argued they had taken this into account.[14]

On June 15, 2010, the FDA approved the first diagnostic test capable of detecting HIV antigens and HIV antibodies. The Abbott

ARCHITECT HIV Ag/Ab combo test, a fourth-generation test, has an increased sensitivity for detecting infections during the acute phase (when compared to 1st and 3rd generation tests), when the immune system is still developing antibodies and the virus is replicating unchecked, and in one study, was able to detect 83% of such infections.[15]

Society and culture

A person, who may be unaware of the infection, is highly infectious during this time yet may test negative for HIV using tests that detect anti-HIV antibodies only. Although Nucleic Acid Amplification Testing

NAAT is more expensive and can take a week for processing, some have argued that it may still be a preferred way to screen for HIV.[3]

Contagiousness

The higher the viral load value, the more viral elements there are in blood and other body fluids. For example, individuals with HIV are most contagious during the earliest (acute) stages of the infection, sometimes with millions of copies of HIV per centiliter of blood. According to one estimate, the majority of transmissions among gay men in the UK occur during primary infection.[16] This is because, at this phase, the immune response is still developing. Antibody levels against the virus during acute infection are often too low to be detected, meaning that an antibody test for a highly infectious individual can come back negative.[citation needed]

There is at least one documented case of an HIV-positive individual with an undetectable viral load infecting his partner.[17] Nevertheless, two recent major studies of serodiscordant couples in which the positive partner had an undetectable viral load have found no linked transmission events despite at least some unprotected sex among the couples.[18][19] HPTN 052, a third study, found one linked transmission event in a test group of 886 couples,[20] although it is unclear whether the originally infected partner in this case had achieved an undetectable viral load at the time of transmission.[21]

Viral load in blood corresponds imperfectly to viral load in other parts of the body. Individuals with undetectable viral loads in their blood might not have undetectable viral loads in other bodily fluids, such as semen or vaginal secretions. In one recent study, of 83 men with undetectable viral loads, 21 had very slight but not undetectable viral loads in their semen.[22] However, it is unclear how much this actually increases transmission risk.[citation needed]

Distributors

Nucleic acid test

Nucleic acid tests are a typical way to measure viral load, including for HIV.

HIV NATs for viral load approved & licensed by the FDA for sale in the United States[23]
Test name Molecular method Use Approved Manufacturer
Roche Amplicor HIV-1 Monitor Test[24] PCR Viral load 3/2/1999
Roche Molecular Systems, Inc.
Pleasanton, CA
NucliSens HIV-1 QT[25] NASBA Viral load 11/19/2001 bioMerieux, Inc Durham, NC
Trugene HIV-1 Genotyping Kit and Open Gene DNA Sequencing System[26] HIV-1 Genotyping Patient monitoring 4/24/2002 Siemens Medical Solutions Diagnostics Berkeley, CA
ViroSeq HIV-1 Genotyping System with the 3700 Genetic Analyzer[27] HIV-1 Genotyping Patient monitoring 6/11/2003 Celera Diagnostics Alameda, CA
Versant HIV-1 RNA 3.0[28]
bDNA
Patient monitoring 9/11/2002 Siemens Medical Solutions Diagnostics Berkeley, CA
Procleix Ultrio Assay[29] TMA (commercial variation of NASBA)

The three steps to the Procleix Ultrio Assay are done in one tube.

luminometer is used to measure the signal. The sensitivity of this assay
is 98%.

Qualitative detection of HIV-1 RNA and hepatitis C virus (HCV) RNA from volunteer donors of whole blood and blood components, screen of live organ donors, and test blood specimens to screen cadaveric donors. HBV screening of individual samples and pooled samples. 10/3/2006 Gen-Probe San Diego, CA US Licence 1592 Chiron Corporation
Human Immunodeficiency Virus, Type 1 (HIV-1) Reverse Transcription (RT) Polymerase Chain Reaction (PCR) Assay[31] PCR Qualitative detection of HIV-1 RNA in pools of human Source Plasma 1/31/2007 BioLife Plasma Services, L.P. Deerfield, IL US Licence 1640
Abbott RealTime HIV-1 Amplification Kit[32]
RT-PCR

The sensitivity (linear range) for this assay is 40 copies/mL to 1010 copies/mL. Two probes are used. The HIV-1 probe is labeled with a

quencher
molecule attached complementary to the 5' end of the HIV-1 probe. If the HIV-1 probe finds and attaches to a HIV target the quencher molecule is released and the resulting fluorescent emission is measured. The fluorescence is proportional to the log of the amount of virus in the sample.

Quantitation of HIV-1 5/11/2007 ABBOTT Molecular, Inc Des Plaines, IL
COBAS AmpliPrep/COBAS TaqMan HIV-1 Test[33] PCR

Uses

base pairs
(bp) on the target sequences. The energy is emitted in the form of heat or fluorescence. The probes are designed to bind 1-5 bp from each other. The energy emission is proportional to the concentration of viral particles. The linear range for this assay is 48 copies/mL of blood.

Quantitation of HIV-1 5/11/2007
Roche Molecular Systems, Inc
Pleasanton, CA

Non-nucleic acid-based tests

ExaVir™ Load Archived 2011-10-28 at the Wayback Machine Version 3 from Cavidi AB is a largely manual test, which has the European regulatory approval (CE-Mark) for clinical use and is also used for viral load monitoring. Virus-associated reverse transcriptase (RT) activity is measured and can therefore detect all types and subtypes of HIV.[2] The technology does not require sophisticated laboratories.[34][35]

References

  1. ^ a b c d e f g h i j HIV Medicine Association (February 2016), "Five Things Physicians and Patients Should Question", Choosing Wisely: an initiative of the ABIFoundation, HIV Medicine Association, retrieved 9 May 2016
  2. ^
    S2CID 11551779
    .
  3. ^
    PMID 22442319.{{cite journal}}: CS1 maint: multiple names: authors list (link
    )
  4. ^ DHHS Panel on Antiretroviral Guidelines for Adults and Adolescents. Guidelines for the Use of Antiretroviral Agents in HIV-1-Infected Adults and Adolescents. May 4, 2006. (available for download from AIDSInfo)
  5. ^ U.S. Department of Health and Human Services. 2009. HIV and Its Treatment: What You Should Know. Available for download from https://aidsinfo.nih.gov/contentfiles/lvguidelines/PerinatalGL.pdf Archived 2015-05-14 at the Wayback Machine
  6. ^ Carter M. (2008). Most viral load blips are short-lasting and of no significance. NAM Publications. Available at http://www.aidsmap.com/Most-viral-load-blips-are-short-lasting-and-of-no-significance/page/1430421/
  7. ^ Testing Window Period. (2010). aids.gov. Available at http://aids.gov/hiv-aids-basics/prevention/your-hiv-status/testing-window-period/
  8. ^ IV. The Challenge of Diagnosis. The United States President's Emergency Plan for Aids Relief. Available at http://www.pepfar.gov/progress/76907.htm
  9. S2CID 33073998
    .
  10. .
  11. .
  12. ^ .
  13. .
  14. .
  15. PMID 21983253.{{cite journal}}: CS1 maint: multiple names: authors list (link
    )
  16. . Retrieved 2015-02-01.
  17. .
  18. ^ Category: Treatment as Prevention. "CROI 2014: HIV Transmission through Condomless Sex [VIDEO] | Treatment as Prevention". hivandhepatitis.com. Archived from the original on 2015-02-08. Retrieved 2015-02-01.
  19. ^ Derek Thaczuk Published: 15 November 2006 (2006-11-15). "HIV & AIDS Information :: Spanish find that serodiscordant couples having unprotected sex to conceive - no cases of HIV transmission". Aidsmap.com. Retrieved 2015-02-01.{{cite web}}: CS1 maint: numeric names: authors list (link)
  20. PMID 21767103
    .
  21. ^ ""Focusing specifically on the one HIV transmission that occurred in the immediate treatment group, Cohen noted that the HIV-negative partner tested positive for the virus—using standard Western blot testing—on day 85 of the study, whereas the HIV-positive partner's first undetectable viral load was documented 28 days after entering the study. The researchers believe that the HIV-negative partner was infected at least 50 days before testing positive, likely 84 to 190 days earlier. In other words, the HIV-negative partner was likely infected with the virus before the HIV-positive partner was able to achieve an undetectable viral load while on treatment."".[permanent dead link]
  22. ^ "Top Stories : Undetectable Viral Load? Not Necessarily in Semen - by Tim Horn". Aidsmeds.com. 2012-04-03. Archived from the original on 2014-12-21. Retrieved 2015-02-01.
  23. ^ Complete List of Donor Screening Assays for Infectious Agents and HIV Diagnostic Assays. US Food & Drug Administration. November 30, 2010. (available to download from https://www.fda.gov/BiologicsBloodVaccines/BloodBloodProducts/ApprovedProducts/LicensedProductsBLAs/BloodDonorScreening/InfectiousDisease/UCM080466
  24. ^ Consumer Affairs Branch (CBER) (2010-08-17). "Roche Amplicor HIV-1 Monitor Test". Fda.gov. Retrieved 2012-10-16.
  25. ^ Consumer Affairs Branch (CBER). "NucliSens HIV-1 QT". Fda.gov. Retrieved 2012-10-16.
  26. ^ "TRUGENE® HIV-1 Genotyping Kit and OpenGene® DNA Sequencing System- BK110007". Fda.gov. 2011-03-10. Retrieved 2012-10-16.
  27. ^ "ViroSeq HIV-1 Genotyping System with the 3700 Genetic Analyzer". Fda.gov. Retrieved 2012-10-16.
  28. ^ Consumer Affairs Branch (CBER). "VERSANT HIV-1 RNA 3.0 Assay (bDNA)". Fda.gov. Retrieved 2012-10-16.
  29. ^ Consumer Affairs Branch (CBER). "Procleix Ultrio Plus Assay". Fda.gov. Retrieved 2012-10-16.
  30. S2CID 19341821
    .
  31. ^ "Human Immunodeficiency Virus, Type 1 (HIV-1) Reverse Transcription (RT) Polymerase Chain Reaction (PCR) Assay". Fda.gov. 2007-01-31. Retrieved 2012-10-16.
  32. ^ Consumer Affairs Branch (CBER) (2009-02-18). "Abbott RealTime HIV-1 Amplification Reagent Kit, Abbott RealTime HIV-1 Calibrator Kit, Abbott RealTime HIV-1 Control Kit". Fda.gov. Retrieved 2012-10-16.
  33. ^ Consumer Affairs Branch (CBER) (2009-02-19). "COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, 48 Tests; COBAS AmpliPrep/COBAS TaqMan Wash Reagent, 5.1 L". Fda.gov. Retrieved 2012-10-16.
  34. PMID 15853722. Archived from the original
    on 2015-01-03. Retrieved 2016-05-26.
  35. .

External links