Micro-CT has applications both in medical imaging and in industrial computed tomography. In general, there are two types of scanner setups. In one setup, the X-ray source and detector are typically stationary during the scan while the sample/animal rotates. The second setup, much more like a clinical CT scanner, is gantry based where the animal/specimen is stationary in space while the X-ray tube and detector rotate around. These scanners are typically used for small animals (in vivo scanners), biomedical samples, foods, microfossils, and other studies for which minute detail is desired.
The first X-ray microtomography system was conceived and built by Jim Elliott in the early 1980s. The first published X-ray microtomographic images were reconstructed slices of a small tropical snail, with pixel size about 50 micrometers.[5]
Working principle
Imaging system
Fan beam reconstruction
The fan-beam system is based on a one-dimensional (1D) X-ray detector and an electronic X-ray source, creating 2D
Cone beam reconstruction
The cone-beam system is based on a 2D X-ray detector (camera) and an electronic X-ray source, creating projection images that later will be used to reconstruct the image cross-sections.
Open/Closed systems
Open X-ray system
In an open system, X-rays may escape or leak out, thus the operator must stay behind a shield, have special protective clothing, or operate the scanner from a distance or a different room. Typical examples of these scanners are the human versions, or designed for big objects.
Closed X-ray system
In a closed system, X-ray shielding is put around the scanner so the operator can put the scanner on a desk or special table. Although the scanner is shielded, care must be taken and the operator usually carries a dosimeter, since X-rays have a tendency to be absorbed by metal and then re-emitted like an antenna. Although a typical scanner will produce a relatively harmless volume of X-rays, repeated scannings in a short timeframe could pose a danger. Digital detectors with small pixel pitches and micro-focus x-ray tubes are usually employed to yield in high resolution images.[6]
Closed systems tend to become very heavy because lead is used to shield the X-rays. Therefore, the smaller scanners only have a small space for samples.
3D image reconstruction
The principle
Because microtomography scanners offer isotropic, or near isotropic, resolution, display of images does not need to be restricted to the conventional axial images. Instead, it is possible for a software program to build a volume by 'stacking' the individual slices one on top of the other. The program may then display the volume in an alternative manner.[7]
Image reconstruction software
For X-ray microtomography, powerful open source software is available, such as the ASTRA toolbox.[8][9] The ASTRA Toolbox is a MATLAB and python toolbox of high-performance GPU primitives for 2D and 3D tomography, from 2009 to 2014 developed by iMinds-Vision Lab, University of Antwerp and since 2014 jointly developed by iMinds-VisionLab, UAntwerpen and CWI, Amsterdam. The toolbox supports parallel, fan, and cone beam, with highly flexible source/detector positioning. A large number of reconstruction algorithms are available, including FBP, ART, SIRT, SART, CGLS.[10]
For 3D visualization, tomviz is a popular open-source tool for tomography.[citation needed]
Volume rendering
Volume rendering is a technique used to display a 2D projection of a 3D discretely sampled data set, as produced by a microtomography scanner. Usually these are acquired in a regular pattern, e.g., one slice every millimeter, and usually have a regular number of image pixels in a regular pattern. This is an example of a regular volumetric grid, with each volume element, or voxel represented by a single value that is obtained by sampling the immediate area surrounding the voxel.
Image segmentation
Where different structures have similar threshold density, it can become impossible to separate them simply by adjusting volume rendering parameters. The solution is called
Typical use
Archaeology
- Reconstructing fire-damaged artifacts, such as the En-Gedi Scroll and Herculaneum papyri
- Unpacking cuneiform tablets wrapped in clay envelopes[13] and clay tokens
Biomedical
- Both in vitro and in vivo small animal imaging
- Neurons[14]
- Human skin samples
- Bone samples, including teeth,[15] ranging in size from rodents to human biopsies
- Lung imaging using respiratory gating
- Cardiovascular imaging using cardiac gating
- Imaging of the human eye, ocular microstructures and tumors[16]
- Tumor imaging (may require contrast agents)
- Soft tissue imaging[17]
- Insects[18] – Insect development[19][20]
- Parasitology – migration of parasites,[21] parasite morphology[22][23]
- Tablet consistency checks[24]
- Tracing the development of the extinct Tasmanian tiger during growth in the pouch[25]
- Model and non-model organisms (elephants,[26] zebrafish,[27] and whales[28])
Electronics
- Small electronic components. E.g. DRAM ICin plastic case.
Microdevices
Composite materials and metallic foams
- Ceramics and Ceramic–Metal composites.[1] Microstructural analysis and failure investigation
- Composite material with glass fibers 10 to 12 micrometres in diameter
Polymers, plastics
- Plastic foam
Diamonds
- Detecting defects in a diamond and finding the best way to cut it.
Food and seeds
- 3-D imaging of foods[29]
- Analysing heat and drought stress on food crops[30]
- Bubble detection in squeaky cheese[31]
Wood and paper
- Piece of wood to visualize year periodicity and cell structure
Building materials
- Concrete after loading
Geology
In geology it is used to analyze micro pores in the reservoir rocks,[32][33] it can used in microfacies analysis for sequence stratigraphy. In petroleum exploration it is used to model the petroleum flow under micro pores and nano particles.
It can give a resolution up to 1 nm.
Fossils
- Vertebrates
- Invertebrates[36]
Microfossils
- Benthonic foraminifers
Palaeography
- Digitally unfolding letters of correspondence which employed letterlocking.[38][39]
Space
- Locating stardust-like particles in aerogel using X-ray techniques[40]
- Samples returned from asteroid 25143 Itokawa by the Hayabusa mission[41]
Stereo images
- Visualizing with blue and green or blue filters to see depth
Others
- Cigarettes
- Social insect nests[42]
See also
References
- ^ S2CID 201645244.
- ^ X-Ray+Microtomography at the U.S. National Library of Medicine Medical Subject Headings (MeSH)
- PMID 16870669.
- PMID 23308240.
- S2CID 2231984.
- PMID 26640309.
- ISBN 978-3-319-59573-3.
- PMID 26057688.
- PMID 27828452.
- ^ A Quasi-realtime X-ray Microtomography System at the Advanced Photon Source. United States. Department of Energy. 1999.
- S2CID 5722082.
- S2CID 229386129.
- ^
Unpacking a Cuneiform Tablet wrapped in a clay envelope on YouTube. Data processing and visualization using the GigaMesh Software Framework, cf. doi:10.11588/heidok.00026892.
- S2CID 195805317.
- PMID 23380275. Retrieved 3 March 2021.
- PMID 28129364.
- S2CID 13261178.
- S2CID 8527127.
- PMID 23676900.
- PMID 28465577.
- PMID 26897588.
- hdl:1956/12721.
- PMID 27441121.
- S2CID 251981681.
- PMID 29515893.
- PMID 22298853.
- PMID 31063133.
- S2CID 43353096.
- ^ Gerard van Dalen, Han Blonk, Henrie van Aalst, Cris Luengo Hendriks 3-D Imaging of Foods Using X-Ray Microtomography Archived July 19, 2011, at the Wayback Machine. G.I.T. Imaging & Microscopy (March 2003), pp. 18–21
- PMID 29118820.
- S2CID 262087123.
- S2CID 224851782.
- S2CID 104311947.
- ISSN 0098-3004.
- S2CID 230555156.
- PMID 19656861.
- .
- ^ Castellanos, Sara (2 March 2021). "A Letter Sealed for Centuries Has Been Read—Without Even Opening It". The Wall Street Journal. Retrieved 2 March 2021.
- PMID 33654094.
- Bibcode:2003LPI....34.1228J.
- S2CID 206534927.
- PMID 28057831.
External links
- MicroComputed Tomography: Methodology and Applications
- Synchrotron and non synchrotron X-ray microtomography threedimensional representation of bone ingrowth in calcium phosphate biomaterials
- Microfocus X-ray Computer Tomography in Materials Research
- Locating Stardust-like particles in aerogel using x-ray techniques
- Use of micro CT to study kidney stones
- Use of micro CT in ophthalmology
- Application of the Gatan X-ray Ultramicroscope (XuM) to the Investigation of Material and Biological Samples