Ultrasonic flow meter
![](http://upload.wikimedia.org/wikipedia/commons/1/12/Tttecnology.gif)
An ultrasonic flow meter is a type of
Means of operation
There are three different types of ultrasonic flow meters. Transmission (or contrapropagating transit-time) flow meters can be distinguished into in-line (intrusive, wetted) and clamp-on (non-intrusive) varieties. Ultrasonic flow meters that use the Doppler shift are called reflection or Doppler flow meters. The third type is the open-channel flow meter.[1]
Principle
Time transit flow meter
Ultrasonic flow meters measure the difference between the transit time of ultrasonic pulses propagating with and against the flow direction. This time difference is a measure for the average velocity of the fluid along the path of the ultrasonic beam. By using the absolute transit times and , both the averaged fluid velocity and the speed of sound can be calculated. Using these two transit times, the distance between receiving and transmitting transducers and the inclination angle , if we assume that sound has to go against the flow when going up and along the flow when returning down, then one can write the following equations from the definition of velocity:
and
By adding and subtracting the above equations we get,
and
where is the average velocity of the fluid along the sound path and is the speed of sound.
Doppler shift flow meters
Another method in ultrasonic flow metering is the use of the
Doppler flowmeters are used for
This type of flow meter can also be used to measure the rate of blood flow, by passing an ultrasonic beam through the tissues, bouncing it off a reflective plate, then reversing the direction of the beam and repeating the measurement, the volume of blood flow can be estimated. The frequency of the transmitted beam is affected by the movement of blood in the vessel and by comparing the frequency of the upstream beam versus downstream the flow of blood through the vessel can be measured. The difference between the two frequencies is a measure of true volume flow. A wide-beam sensor can also be used to measure flow independent of the cross-sectional area of the blood vessel.
Open channel flow meters
In this case, the ultrasonic element is actually measuring the height of the water in the open channel; based on the geometry of the channel, the flow can be determined from the height. The ultrasonic sensor usually also has a temperature sensor with it because the speed of sound in air is affected by the temperature.
See also
- Flow measurement
- Magnetic flow meter
- Turbine flow meter
References
- Lipták, Béla G.: Process Measurement and Analysis, Volume 1. CRC Press (2003), ISBN 0-8493-1083-0(v. 1)
- Ultrasonic Acoustic Sensing Brown University
- Lynnworth, L.C.: Ultrasonic Measurements for Process Control. Academic Press, Inc. San Diego. ISBN 0-12-460585-0