Antiresonance
In the
Antiresonances can occur in all types of coupled oscillator systems, including mechanical, acoustical, electromagnetic, and quantum systems. They have important applications in the characterization of complicated coupled systems.
The term antiresonance is used in electrical engineering for a form of resonance in a single oscillator with similar effects.
Antiresonance in electrical engineering
In
In an electric circuit consisting of a capacitor and an inductor in parallel, antiresonance occurs when the alternating current line voltage and the resultant current are in phase.[1] Under these conditions the line current is very small because of the high electrical impedance of the parallel circuit at antiresonance. The branch currents are almost equal in magnitude and opposite in phase.[2]
Antiresonance in coupled oscillators
The simplest system in which antiresonance arises is a system of coupled
Consider two harmonic oscillators coupled together with strength g and with one oscillator driven by an oscillating external force F. The situation is described by the coupled ordinary differential equations
where the ωi represent the resonance frequencies of the two oscillators and the γi their
allows us to write these as first-order equations:
We transform to a frame rotating at the driving frequency
yielding
where we have introduced the detunings Δi = ω − ωi between the drive and the oscillators' resonance frequencies. Finally, we make a
Without damping, driving or coupling, the solutions to these equations are:
which represent a rotation in the complex α plane with angular frequency Δ.
The
Examining these steady state solutions as a function of driving frequency, it is evident that both oscillators display resonances (peaks in amplitude accompanied by positive phase shifts) at the two
Interpretation as destructive interference
The reduced oscillation amplitude at an antiresonance can be regarded as due to destructive
In the above example, at the antiresonance frequency the external driving force F acting on oscillator 1 cancels the force acting via the coupling to oscillator 2, causing oscillator 1 to remain almost stationary.
Complicated coupled systems
The frequency response function (FRF) of any linear dynamic system composed of many coupled components will in general display distinctive resonance-antiresonance behavior when driven.[3]
As a rule of thumb, it can be stated that as the distance between the driven component and the measured component increases, the number of antiresonances in the FRF decreases.[4] For example, in the two-oscillator situation above, the FRF of the undriven oscillator displayed no antiresonance. Resonances and antiresonances only alternate continuously in the FRF of the driven component itself.
Applications
An important result in the theory of antiresonances is that they can be interpreted as the resonances of the system fixed at the excitation point.[4] This can be seen in the pendulum animation above: the steady-state antiresonant situation is the same as if the left pendulum were fixed and could not oscillate. An important corollary of this result is that the antiresonances of a system are independent of the properties of the driven oscillator; that is, they do not change if the resonance frequency or damping coefficient of the driven oscillator are altered.
This result makes antiresonances useful in characterizing complex coupled systems which cannot be easily separated into their constituent components. The resonance frequencies of the system depend on the properties of all components and their couplings, and are independent of which is driven. The antiresonances, on the other hand, are dependent upon everything except the component being driven, therefore providing information about how it affects the total system. By driving each component in turn, information about all of the individual subsystems can be obtained, despite the couplings between them. This technique has applications in mechanical engineering, structural analysis,[5] and the design of integrated quantum circuits.[6]
In electrical engineering antiresonance is used in
In nanomechanical systems, the sideband spectra of a driven nonlinear mode with its eigenfrequency being modulated at a low frequency (<1 kHz) shows prominent antiresonance line shapes in the power spectra, which can be controlled through the vibration state. The antiresonance frequency can be utilized to characterize the thermal fluctuation and the squeezing parameter of the nonlinear system. [9]
See also
- Resonance
- Oscillator
- Resonance (alternating-current circuits)
- Tuned mass damper
- Fano resonance
References
- ISBN 0-471-84789-5.
- ISBN 0-471-66782-X.
- ^ Ewins, D. J. (1984). Modal Testing: Theory and Practice. New York: Wiley.
- ^ .
- .
- S2CID 30259173.
- ISBN 0-471-44878-8.
- ISBN 978-0-07-154452-8.
- S2CID 236171156.