Diastolic function
In clinical
How the heart works during its filling period still has many misconceptions remaining. To better understand diastolic function, it is crucial to realize that the left
During diastole, the ventricle of heart must remain elastic or compliant enough and have capacity to hold incoming blood to guarantee effectiveness of the filling phase. Hence stiffness and relaxation are ventricle's intrinsic feature parameters that are practical in evaluating and quantifying diastolic function.[9] In addition, volumetric load[10] serves as an extrinsic indicating parameter that modulates diastolic function.
Measurement
The most established index to describe left ventricular diastolic function is Tau, left ventricular diastolic time constant. Measurement of Tau is traditionally delivered in a catheter lab by an invasive method. Recently, non-invasive measurement of Tau is available for mitral regurgitation or aortic regurgitation patients in an Echo lab.[11]
There have been many attempts intending for extracting both intrinsic and extrinsic properties. Early attempts concentrated on pulse-wave Doppler-echo measured trans-mitral flow velocity contours.[citation needed]
In terms of filling, diastolic intervals consist of early rapid filling E-waves followed by diastasis and followed by atrial systole-generated A-waves. Empirically, E- and A- wave contours were simplified as triangles. Nowadays, triangle-based indexes, such as the peak velocities of the E- and A-waves and ratio of them, the deceleration time and time duration of the E-wave, and the velocity time integral of both E- and A- waves, are usually measured and evaluated.[citation needed]
The triangular approach applies to E-wave shape conveniently, especially in the past when the images rendered by technology back in days are of poor resolution quality. Nevertheless, with rapidly improving temporal resolution and image processing capabilities, the curvature of E-wave contours can be clearly identified with detailed information revealed.
Due to advancement of modern medical imaging technology, the measurement of even smaller (i.e. tissue) velocities are possible to be made, which even leads to capability to measure the longitudinal displacements of the
Other innovative imaging modalities consist of techniques such as speckle tracking. Speckle tracking enables strain and strain-rate measurements. It is a relatively recent instance of technological progress, due to the fact that it relies on the information content inherent in the seemingly random arrangement of bright speckles present in all echocardiographic images.[12] Even though a variety of echo-based imaging technologies represent multiple levels of research innovation, much remains to be studied in relation to how to interpret the recorded data embedded in images.
References
- PMID 19270053.
- ^ "Ejection Fraction | Cleveland Clinic". Cleveland Clinic. Retrieved 2017-01-26.
- PMID 25182014.
- )
- S2CID 12453342.
- ISSN 0002-9513.
- PMID 3704622.
- PMID 2678168.
- ^ a b Burkhoff, Daniel (2002). "MECHANICAL PROPERTIES OF THE HEART AND ITS INTERACTION WITH THE VASCULAR SYSTEM" (PDF). Cardiac Physiology: 1–23 – via Columbia University.
- PMID 2454344.
- S2CID 205539634.
- PMID 16286606.