Calcium imaging

Source: Wikipedia, the free encyclopedia.

Calcium imaging is a

calcium signalling in a wide variety of cell types. In neurons, action potential generation is always accompanied by rapid influx of Ca2+ ions. Thus, calcium imaging can be used to monitor the electrical activity in hundreds of neurons in cell culture or in living animals, which has made it possible to observe the activity of neuronal circuits during ongoing behavior.[2]

Chemical indicators

Schematic of a typical setup for calcium fluorescence imaging of isolated cardiac myocytes

Chemical indicators are small molecules that can

EGTA homologue called BAPTA, with high selectivity for calcium (Ca2+) ions versus magnesium
(Mg2+) ions.

This group of indicators includes fura-2, indo-1, fluo-3, fluo-4, Calcium Green-1.

These dyes are often used with the chelator

mitochondria.[4]

Calcium imaging, also referred to as calcium mapping, is also used to perform research on myocardial tissue.[5] Calcium mapping is a ubiquitous technique used on whole, isolated hearts such as mouse, rat, and rabbit species.

Genetically encoded calcium indicators

Genetically encoded calcium indicators (GECIs) are powerful tools useful for in vivo imaging of cellular, developmental, and physiological processes.

cardiomyocytes,[13] and other cell types. Some GECIs report calcium by direct emission of photons (luminescence), but most rely on fluorescent proteins as reporters, including the green fluorescent protein GFP
and its variants (eGFP, YFP, CFP).

Of the fluorescent reporters, calcium indicator systems can be classified into single fluorescent protein (FP) systems, and paired fluorescent protein systems. Camgaroos were one of the first developed variants involving a single protein system. Camgaroos take advantage of calmodulin (CaM), a calcium binding protein. In these structures, CaM is inserted in the middle of yellow fluorescent protein (YFP) at Y145. Previous mutagenesis studies revealed that mutations at this position conferred pH stability while maintaining fluorescent properties, making Y145 an insertion point of interest. Additionally, the N and C termini of YFP are linked by a peptide linker (GGTGGS). When CaM binds to Ca2+, the effective pKa is lowered, allowing for chromophore deprotonation.[14] This results in increased fluorescence upon calcium binding in an intensiometric fashion. Such detection is in contrast with ratiometric systems, in which there is a change in the absorbance/emission spectra as a result of Ca2+ binding.[15] A later developed single-FP system, dubbed G-CaMP, also invokes circularly permuted GFP. One of the termini is fused with CaM, and the other termini is fused with M13 (the calmodulin binding domain of myosin light kinase)[16] The protein is designed such that the termini are close in space, allowing for Ca2+ binding to cause conformational changes and chromophore modulation, allowing for increased fluorescence. G-CaMP and its refined variants have nanomolar binding affinities.[17] A final single protein variant is the CatchER, which is generally considered to be a lower affinity indicator. Its calcium binding pocket is quite negative; binding of the cation helps to shield the large concentration of negative charge and allows for recovered fluorescence.[18]

In contrast to these systems are paired fluorescent protein systems, which include the prototypical Cameleons. Cameleons consist of two different fluorescent proteins, CaM, M13, and a glycylglycine linker.[15] In the absence of Ca2+, only the donor blue-shifted fluorescent protein will be fluorescent. However, a conformational change caused by calcium binding repositions the red-shifted fluorescent protein, allowing for FRET (Förster resonance energy transfer) to take place. Cameleon indicators produce a ratiometric signal (i.e. the measured FRET efficiency depends on the calcium concentration). Original variants of cameleons were originally more sensitive to Ca2+ and were acid quenched.[19] Such shortcomings were abrogated by Q69K and V68L mutations. Both of these residues were close to the buried anionic chromophore and these mutations probably hinder protonation, conferring greater pH resistance.

Of growing importance in calcium detection are near-IR (NIR) GECIs, which may open up avenues for multiplexing different indicator systems and allowing deeper tissue penetration. NIRs rely on biliverdin-binding fluorescent proteins, which are largely derived from bacterial phytochromes. NIR systems are similar to inverse pericams in that both experience a decrease in fluorescence upon Ca2+ binding. RCaMPs and RGECOs are functional at 700+ nm, but are quite dim.[20] A Cameleon analog involving NIR FRET has been successfully constructed as well.[21]

A special class of GECIs are designed to form a permanent fluorescent tag in active neurons. They are based on the photoswitchable protein Eos which turns from green to red through photocatalyzed (with violet light) backbone cleavage.[22] Combined with the CaM, violet light photoconverts only neurons that have elevated calcium levels. SynTagMA is a synapse-targeted version of CaMPARI2.[23]

While fluorescent systems are widely used, bioluminescent Ca2+ reporters may also hold potential because of their ability to abrogate autofluorescence, photobleaching [no excitation wavelength is needed], biological degradation and toxicity, in addition to higher signal-to-noise ratios.[24] Such systems may rely on aequorin and the luciferin coelenterazine. Ca2+ binding causes a conformational change that facilitates coelenterazine oxidation. The resultant photoproduct emits blue light as it returns to the ground state. Colocalization of aequorin with GFP facilitates BRET/CRET (Bioluminescence or Chemiluminescence Resonance Energy Transfer),[18] resulting in a 19 - 65 brightness increase. Such structures can be used to probe millimolar to nanomolar calcium concentrations. A similar system invokes obelin and its luciferin coelenteramide, which may possess faster calcium response time and Mg2+ insensitivity than its aqueorin counterpart.[25] Such systems can also leverage the self-assembly of luciferase components. In a system dubbed “nano-lantern,” the luciferase RLuc8 is split and placed on different ends of CaM. Calcium binding brings the RLuc8 components in close proximity, reforming luciferase, and allowing it to transfer to an acceptor fluorescent protein.

To minimize damage to the visualized cells, two-photon microscopy is often invoked to detect the fluorescence from the reporters.[26] The use of near-IR wavelengths and minimization of axial spread of the point function[27] allows for nanometer resolution and deep penetration into the tissue. The dynamic range is often determined from such measurements. For non-ratiometric indicators (typically single protein indicators), it is the ratio of the fluorescence intensities obtained under Ca2+ saturated and depleted conditions, respectively. However, for ratiometric indicators, the dynamic range is the ratio of the maximum FRET efficiency ratio (calcium saturated) to the minimum FRET efficiency ratio (calcium depleted). Yet another common quantity used to measure signals produced by calcium concentration fluxes is the signal-to-baseline ratio (SBR), which is simply the ratio of the change in fluorescence (F - F0) over the baseline fluorescence. This can be related to the SNR (signal to noise ratio) by multiplying the SBR by the square root of the number of counted photons.[18]

GECI Year Sensing Reporting Precursor
Cameleons[28] 1997 Calmodulin FRET pair: BFP or CFP, and GFP or YFP -
FIP-CBSM[29] 1997 Calmodulin FRET pair: BFP and RFP -
Pericams[30] 2000 Calmodulin cpGFP -
GCaMP[17][31] 2000 Calmodulin cpEGFP -
TN-L15[32] 2004 Modified chicken skeletal muscle troponin C FRET pair: YFP (Citrine) and CFP (Cerulean) -
TN-humTnC[32] 2004 Human cardiac troponin C FRET pair: YFP (Citrine) and CFP (Cerulean) -
TN-XL[33] 2006 Modified chicken skeletal muscle troponin C FRET pair: permuted YFP (Citrine) and CFP (Cerulean) TN-L15
TN-XXL[34] 2008 Modified csTnC in TN-XL FRET pair: permuted YFP (Citrine) and CFP (Cerulean) TN-XL
Twitch's[35] 2014 Troponin C FRET pair (various of two FPs) -
RCaMP1[36] 2013 Calmodulin mRuby (red FP) -
jRGECO1a[37] 2016 Calmodulin mApple (red FP) R-GECO[38]

A special class of genetically encoded calcium indicators are designed to form a permanent fluorescent tag in active neurons. They are based on the photoswitchable protein mEos which turns from green to red when illuminated with violet light. Combined with the calcium sensor calmodulin, violet light photoconverts only neurons that have elevated calcium levels. SynTagMA is a synapse-targeted version of CaMPARI2.

GECI Year Sensing Reporting Precursor
CaMPARI[23] 2015 Calmodulin + violet light mEos: green to red conversion -
CaMPARI2[39] 2018 Calmodulin + violet light mEos: green to red conversion CaMPARI
SynTagMA[40] 2020 Calmodulin + violet light mEos: green to red conversion CaMPARI2
TubuTag[41] 2021 Calmodulin + violet light mEos: green to red conversion CaMPARI2

Usage

Regardless of the type of indicator used, the imaging procedure is generally very similar. Cells loaded with an indicator, or expressing it in the case of a GECI,

synaptic boutons, even in thick samples such as mammalian brains. Images are analyzed by measuring fluorescence intensity changes for a single wavelength or two wavelengths expressed as a ratio (ratiometric indicators). If necessary, the derived fluorescence intensities and ratios may be plotted against calibrated values for known Ca2+ levels to measure absolute Ca2+ concentrations. Light field microscopy methods[44]
extend functional readout of neural activity capabilities in 3D volumes.

Methods such as

offer calcium imaging in freely behaving and head-fixed animal models.

References

Further reading