This mechanism is found very commonly in everyday life, including central heating and air conditioning and in many other machines. Forced convection is often encountered by engineers designing or analyzing heat exchangers, pipe flow, and flow over a plate at a different temperature than the stream (the case of a shuttle wing during re-entry, for example).[1]
Mixed convection
In any forced convection situation, some amount of natural convection is always present whenever there are
Mathematical analysis
When analyzing potentially mixed convection, a parameter called the Archimedes number (Ar) parametrizes the relative strength of free and forced convection. The Archimedes number is the ratio of Grashof number and the square of Reynolds number, which represents the ratio of buoyancy force and inertia force, and which stands in for the contribution of natural convection. When Ar ≫ 1, natural convection dominates and when Ar ≪ 1, forced convection dominates.
When
When the Peclet number is much greater than unity (1), advection dominates diffusion. Similarly, much smaller ratios indicate a higher rate of diffusion relative to advection.