Penile implant
This article may have been created or edited in return for undisclosed payments, a violation of Wikipedia's terms of use. It may require cleanup to comply with Wikipedia's content policies, particularly neutral point of view. (January 2021) |
Penile implant | |
---|---|
![]() Penile implant | |
Other names | Penile prosthesis |
Specialty | Urology |
ICD-10-PCS | 0VUS0JZ |
CPT | 54400, 54405 |
A penile implant is an
History
The first modern prosthetic reconstruction of a penis is attributed to NA Borgus, a German physician who performed the first surgical attempts in 1936 on soldiers with traumatic
According to analysis of the 5% Medicare Public Use Files from 2001 to 2010 approximately 3% of patients diagnosed with erectile dysfunction opt for penile implantation.[15] Each year nearly 25,000 inflatable penile prostheses are implanted in the USA.[16]
The list shows penile implants available in the market in 2020.
Product | Company | Country of origin | Type of the implant | Introduced in |
---|---|---|---|---|
AMS Spectra | Boston Scientific (formerly American Medical Systems) | United States of America
|
Malleable | 2009 |
Tactra | Boston Scientific (formerly American Medical Systems) | United States of America
|
Malleable | 2019 |
Genesis | Coloplast | United States of America
|
Malleable | 2004 |
Shah Indian Malleable | Dr.Rupin Shah | India | Malleable | 2008 |
ZSI 100, ZSI 100 FtM and ZSI 100 D4 | Zephyr Surgical Implants | Switzerland | Malleable | 2012 |
Tube | Promedon | Argentina | Malleable | 2007 |
AMS Ambicor | Boston Scientific (formerly American Medical Systems) | United States of America
|
Inflatable | 1994 |
AMS 700 series (LGX, CX, CXR) | Boston Scientific (formerly American Medical Systems) | United States of America
|
Inflatable | 1983 |
Titan | Coloplast | United States of America
|
Inflatable | 2002 |
ZSI 475 and ZSI 475 FtM | Zephyr Surgical Implants | Switzerland | Inflatable | 2012 |
Infla10 series (AX, X, NarrowBody) | Rigicon Innovative Urological Solutions | United States of America
|
Inflatable | 2019 |
Rigi10[17] | Rigicon Innovative Urological Solutions | United States of America
|
Malleable | 2017 |
Rigi10 Hydrophilic | Rigicon Innovative Urological Solutions | United States of America
|
Malleable | 2019 |
Types
Malleable penile implant
![](http://upload.wikimedia.org/wikipedia/commons/thumb/d/dd/Comparison_of_penile_implants.jpg/350px-Comparison_of_penile_implants.jpg)
![](http://upload.wikimedia.org/wikipedia/commons/thumb/1/13/Penile_implant_pump_design_comparison.jpg/350px-Penile_implant_pump_design_comparison.jpg)
The malleable (also known as non-inflatable or semi-rigid) penile prosthesis is a pair of rods implanted into the corpora of the penis. The rods are hard, but 'malleable' in the sense that they can be adjusted manually into the erect position.[18] There are two types of malleable implants: one that is made of silicone and does not have a rod inside, also called soft implants, and another with a silver or steel spiral wire core inside coated with silicone. Some of the models have trimmable tails intended for length adjustment.[10] Currently, a variety of malleable penile implants are available worldwide.[19]
Inflatable penile implant
The inflatable penile implant (IPP), more recently developed, is a set of inflatable cylinders and a pump system. Based on the differences in structure, there are two types of inflatable penile implants: two-piece and three-piece IPPs. Both types of inflatable devices are filled with sterile saline solution which is pumped into cylinders when in process. The cylinders are implanted into the cavernous body of the penis. The pump system is attached to the cylinders and placed in the scrotum.[10] Three-piece implants have a separate large reservoir connected to the pump. The reservoir is commonly placed in the retropubic space (Retzius' space), however other locations have also been described, such as between the transverse muscle and rectus muscle. Three-piece implants provide more desirable rigidity and girth of the penis resembling natural erection. Additionally, due to the presence of a large reservoir, three-piece implants provide full flaccidity of the penis when deflated, thus bringing more comfort than two-piece inflatable and malleable implants.[6]
The saline solution is pumped manually from the reservoir into bilateral chambers of cylinders implanted in the shaft of the penis, which replaces the non- or minimally-functioning erectile tissue. This produces an erection. The glans of the penis, however, remains unaffected. Ninety to ninety-five percent of inflatable prostheses produce erections suitable for sexual intercourse. In the United States, the inflatable prosthesis has largely replaced the malleable one, due to its lower rate of infections, high device survival rate and 80–90% satisfaction rate.[2]
The first IPP prototype presented in 1975 by Scott and colleagues was a three-piece prosthesis (two cylinders, two pumps and a fluid reservoir). Since then, the IPP has undergone multiple modifications and improvements for device reliability and durability, including change in the chemical material used in implant manufacturing, using hydrophilic and antibiotic eluting coatings to reduce the rates of infections, introducing one-touch release etc.[10] Surgical techniques used for the implantation of penile prostheses have also improved along with evolution of the device. Inflatable penile implants were one of the first interventions in urology where the "no-touch" surgical technique was introduced. This has significantly reduced the rates of post-operative infections.[20]
Medical use
![](http://upload.wikimedia.org/wikipedia/commons/thumb/8/8f/Inflatable_penile_implant.jpg/350px-Inflatable_penile_implant.jpg)
![](http://upload.wikimedia.org/wikipedia/commons/thumb/7/7e/Penile_implant_in_action.gif/250px-Penile_implant_in_action.gif)
Erectile dysfunction
In spite of recent rapid and extensive development of non-surgical management options for erectile dysfunction, especially novel targeted medications and gene therapy, the penile implants remain the mainstay and the gold standard choice for the treatment of erectile dysfunction refractory to oral medications and injectable therapy.[21][6] Additionally, penile implants can be a relevant option for those with erectile dysfunction who want to proceed with a permanent solution without medical therapy. Penile implants have been used for the treatment of erectile dysfunction with various etiologies, including vascular, cavernosal, neurogenic, psychological and post-surgical (e.g. prostatectomy). The American Urological Association recommends informing all men with erectile dysfunction about penile implants as a choice of treatment and discussing the potential outcomes with them.[22]
Penile deformity
Penile implants can help recover the natural shape of the penis in various conditions that have led to penile deformity. These can be traumatic injuries, penile surgeries, disfiguring and fibrosing diseases of the penis, such as Peyronie's disease.[6] In Peyronie's disease, the change in penile curvature affects normal sexual intercourse as well as causing erectile dysfunction due to disruption of blood flow in the cavernous bodies of the penis.[23] Therefore, implantation of penile prosthesis in Peyronie's disease addresses several mechanisms involved in the pathophysiology of the disease.
Female-to-male sex reassignment
Although different models of penile prostheses have been reported to be implanted after
Outcomes
Satisfaction
The overall satisfaction rate with penile implants reaches over 90%.[6] Both self- and partner-reported satisfaction rates are evaluated to assess the outcomes. It has been shown that implantation of inflatable penile prosthesis brings more patient and partner satisfaction than medication therapy with PDE5 inhibitors or intracavernosal injections.[21] Satisfaction rates are reported to be higher with inflatable rather than malleable implants, but there are no differences between two-piece and three-piece devices.[27][28] The most frequent reasons for dissatisfaction are reduced penis length and girth, failed expectations and difficulties with device use.[21][27] Thus, it is vital to provide patients and their partners with detailed preoperative counselling and instructions.[citation needed]
Curvature correction
33% to 90% of cases of patients with Peyronie's disease that have had an inflatable PI procedure have successfully corrected their penile deformity.[23] The residual curvature after penile implant placement usually requires intraoperative surgical intervention.
Progress in procedure
Dilation of the corpora cavernosa, typically with Hegar sounds, before inserting the device has been a common part of implantation procedures. This dilation destroys erectile tissue. It has been shown that a tissue-sparing technique, i.e. without dilation, correlates with superior outcomes – some remaining natural erectile response can be preserved, and post-operative pain is reduced as well.[29][30]
Complications
The most common complication associated with penile implant placement appears to be infections with reported rates of 1–3%.[27] Both surgical site and device infections are reported. When the infection involves the penile implant itself, implant removal is required and irrigation of the cavities with antiseptic solutions. In this scenario, placement of a new implant is needed to avoid further tissue fibrosis and shortening of the penis. The rate of repeat surgeries or device replacements ranges from 6% to 13%.[23] Other reported complications include perforation of the corpus cavernosum and urethra (0.1–3%), commonly occurring in patients with previous fibrosis, prosthesis erosion or extrusion, change in glans shape, hematoma, shortening of penis length, and device malfunction. Due to continuous improvement of surgical techniques and modifications of implants, complication rates have dramatically decreased over time.[citation needed]
To overcome post-operative penile shortening and to increase the perceived length of the penis and patient satisfaction, ventral and dorsal phalloplasty procedures in combination with penile implants have been described.[21] Modified glanulopexy has been proposed to prevent supersonic transporter deformity and glandular hypermobility which are possible complications of penile implants.[31]
Sliding techniques in which the penis is cut and elongated with penile implants have been performed in cases of severe penile shortening. However, these techniques had higher rates of complications and are currently avoided.[citation needed]
References
- PMID 31004096.
- ^ a b Perito, Paul. "Penile Implants". PeritoUrology.com. Perito Urology. Retrieved 12 November 2019.[self-published source?]
- ^ PMID 27871961.
- PMID 13000938.
- S2CID 43779571.
- ^ PMID 29238664.
- ^ PMID 4766860.
- PMID 1093303.
- doi:10.1002/tre.639.
- ^ PMID 28217449.
- S2CID 221019610.
- PMID 31571642.
- S2CID 255971214.
- S2CID 249680998.
- PMID 26096365.
- PMID 23958508.
- ^ "Enforcement Reports" (PDF). www.accessdata.fda.gov.
- ^ Perito, Paul. "Malleable Penile Implant Prosthesis". PeritoUrology.com. Perito Urology. Retrieved 12 November 2019.[self-published source?]
- PMID 25763121.
- PMID 27871962.
- ^ PMID 30828431.
- PMID 29746858.
- ^ PMID 27298781.
- PMID 28940910.
- S2CID 42344243.
- PMID 30638882.
- ^ PMID 30671142.
- S2CID 173992578.
- . Retrieved 14 January 2024.
- . Retrieved 14 January 2024.
- S2CID 24785737.