Osseointegration

Source: Wikipedia, the free encyclopedia.

Osseointegration (from Latin osseus "

amputees.[citation needed
]

Definitions

Osseointegration is also defined as: "the formation of a direct interface between an implant and bone, without intervening soft tissue".[1]

An osseointegrated implant is a type of implant defined as "an endosteal implant containing pores into which osteoblasts and supporting connective tissue can migrate".[2] Applied to oral implantology, this refers to bone grown right up to the implant surface without interposed soft tissue layer. No scar tissue, cartilage or ligament fibers are present between the bone and implant surface. The direct contact of bone and implant surface can be verified microscopically.[citation needed]

Osseointegration may also be defined as:[citation needed]

  1. Osseous integration, the apparent direct attachment or connection of
    osseous tissue
    to an inert alloplastic material without intervening connective tissue.
  2. The process and resultant apparent direct connection of the endogenous material surface and the host bone tissues without intervening connective tissue.
  3. The interface between alloplastic material and bone.

History

Titanium implant (black) integrated into bone (red): Histologic section

Osseointegration was first observed—albeit not explicitly stated—by Bothe, Beaton, and Davenport in 1940.[3][4] Bothe et al. were the first researchers to implant titanium in an animal and remarked how it tended to fuse with bone.[3][4] Bothe et al. reported that due to the elemental nature of the titanium, its strength, and its hardness, it had great potential to be used as future prosthesis material.[3][4] Gottlieb Leventhal later described osseointegration in 1951.[3][5] Leventhal placed titanium screws in rat femurs and said, "At the end of 6 weeks, the screws were slightly tighter than when originally put in; at 12 weeks, the screws were more difficult to remove; and at the end of 16 weeks, the screws were so tight that in one specimen the femur was fractured when an attempt was made to remove the screw. Microscopic examinations of the bone structure revealed no reaction to the implants, the trabeculation appeared to be perfectly normal."[3][5] The reactions described by Leventhal and Bothe et al. would later be coined into the term "osseointegration" by Per-Ingvar Brånemark of Sweden. In 1952, Brånemark did an experiment where he used a titanium implant chamber to study blood flow in rabbit bone. At the end of the experiment, when it became time to remove the titanium chambers from the bone, he discovered that the bone had integrated so completely with the implant that the chamber could not be removed. Brånemark called this "osseointegration", and, like Bothe et al. and Leventhal before him, saw the possibilities for human use.[3][4][5]

In

dental implants into the first human patient—Gösta Larsson. This patient had a cleft palate defect and needed implants to support a palatal obturator. Gösta Larsson died in 2005, with the original implants still in place after 40 years of function.[10]

In the mid-1970s Brånemark entered into a commercial partnership with the Swedish defense company Bofors to manufacture dental implants and the instrumentation required for their placement. Eventually an offshoot of Bofors, Nobel Pharma, was created to concentrate on this product line. Nobel Pharma subsequently became Nobel Biocare.[10]

Brånemark spent almost 30 years fighting the scientific community for acceptance of osseointegration as a viable treatment. In Sweden he was often openly ridiculed at science conferences. His university stopped funding for his research, forcing him to open a private clinic to continue treating patients. Eventually an emerging breed of young academics started to notice the work being done in Sweden. Toronto's George Zarb, a Maltese-born Canadian prosthodontist, was instrumental in bringing the concept of osseointegration to the wider world. The 1983 Toronto Conference is generally considered to be the turning point, when finally the worldwide scientific community accepted Brånemark's work. Osseointegration is now a highly predictable and common treatment modality.[10] Since 2010, Professor Munjed Al Muderis in Sydney, Australia, used a high tensile strength titanium implant with plasma sprayed surface as an intramedullary prosthesis that is inserted into the bone residuum of amputees and then connect through an opening in the skin to a robotic limb prosthesis. This lets amputees mobilize with more comfort and less energy consumption. Al Muderis also published the first series of combining osseointegration prosthesis with Joint replacement enabling below knee amputees with knee arthritis or short residual bone to walk without needing a socket prosthesis.[11]

On December 7, 2015, two Operation Iraqi Freedom/Operation Enduring Freedom veterans, Bryant Jacobs and Ed Salau, became the first in America to get a percutaneous osseointegrated prosthesis.[12] In the first stage, doctors at Salt Lake Veterans Affairs Hospital embedded a titanium stud in the femur of each patient. About six weeks later, they went back and attached the docking mechanism for the prosthesis.[citation needed]

In 2021 Professor Al Muderis published a thesis for the requirements for the Doctor of Medical Science discussing Osseointegration for Amputees: Past, Present and Future - Basic Science, Innovations in Surgical Technique, Implant Design and Rehabilitation Strategies.[13]

Mechanism

Osseointegration is a dynamic process in which characteristics of the implant (i.e. macrogeometry, surface properties, etc.) play a role in modulating molecular and cellular behavior.[14] While osseointegration has been observed using different materials, it is most often used to describe the reaction of bone tissues to titanium, or titanium coated with calcium phosphate derivatives.[15] It was previously thought that titanium implants were retained in bone through the action of mechanical stabilization or interfacial bonding. Alternatively, calcium phosphate coated implants were thought to be stabilized via chemical bonding. It is now known that both calcium phosphate coated implants and titanium implants are stabilized chemically with bone, either through direct contact between calcium and titanium atoms, or by the bonding to a cement line-like layer at the implant/bone interface.[16][17] While there are some differences (e.g. like the lack of chondrogenic progenitors), osseointegration occurs through the same mechanisms as bone fracture healing.[18][19]

Technique

For osseointegrated dental implants, metallic, ceramic, and polymeric materials have been used,[2] in particular titanium.[20] To be termed osseointegration the connection between the bone and the implant need not be 100%, and the essence of osseointegration derives more from the stability of the fixation than the degree of contact in histologic terms. In short it is a process where clinically asymptomatic rigid fixation of alloplastic materials is achieved, and maintained, in bone during functional loading.[21] Implant healing time and initial stability are a function of implant characteristics. For example, implants using a screw-root form design achieve high initial mechanical stability through the action of their screws against bone. Following placement of the implant, healing typically takes several weeks or months before the implant is fully integrated into the bone.[22][23][24] First evidence of integration occurs after a few weeks, while more robust connection is progressively effected over the next months or years.[25] Implants that have a screw-root form design result in bone resorption followed by interfacial bone remodeling and growth around the implant.[26]

Implants using a plateau-root form design (or screw-root form implants with a wide enough gap between the pitch of the screws) undergo a different mode of peri-implant ossification. Unlike the aforementioned screw-root form implants, plateau-root form implants exhibit de novo bone formation on the implant surface.[27] The type of bone healing exhibited by plateau-root form implants is known as intramembranous-like healing.[26]

Though the osseointegrated interface becomes resistant to external shocks over time, it may be damaged by prolonged adverse stimuli and overload, which may cause implant failure.[28][29] In studies done using "Mini dental implants," it was noted that the absence of micromotion at the bone-implant interface was needed to enable proper osseointegration.[30] It was also noted that there is a critical threshold of micromotion above which a fibrous encapsulation process occurs, rather than osseointegration.[31]

Other complications may arise even in the absence of external impact. One issue is growth of cement.[32] In normal cases, absence of cementum on the implant surface prevents attachment of collagen fibers. This is normally the case due to the absence of cementum progenitor cells in the area receiving the implant. However, when such cells are present, cement may form on or around the implant surface, and a functional collagen attachment may attach to it.[33]

Advances in materials engineering: metal foams

Since 2005, a number of orthopedic device makers have introduced products with

tensile strength and corrosion resistance with excellent biocompatibility.[citation needed
]

The process of osseointegration in metal foams is similar to that in

vascularization within the implant. These materials are currently deployed in hip replacement, knee replacement and dental implant surgeries.[citation needed
]

Testing procedures

There are a number of methods used to gauge the level of osseointegration and the subsequent stability of an implant. One widely used diagnostic procedure is percussion analysis, where a dental instrument is tapped against the implant carrier.[38] The nature of the ringing that results is used as a qualitative measure of the implant's stability. An integrated implant will elicit a higher pitched "crystal" sound, whereas a non-integrated implant will elicit a dull, low-pitched sound.[39]

Another method is a reverse torque test, in which the implant carrier is unscrewed. If it fails to unscrew under the reverse torque pressure, the implant is stable. If the implant rotates under the pressure it is deemed a failure and removed.[40] This method comes at the risk of fracturing bone that is mid-way in the process of osseointegration.[38] It is also unreliable in determining the osseointegration potential of a bone region, as tests have yielded that a rotating implant can go on to be successfully integrated.[41]

A non-invasive and increasingly implemented diagnostic method is resonance frequency analysis (RFA).[38] A resonance frequency analyzer device prompts vibrations in a small metal rod temporarily attached to the implant. As the rod vibrates, the probe reads its resonance frequency and translates it into an implant stability quotient (ISQ), which ranges from 1–100, with 100 indicating the highest stability state. Values ranging between 57 and 82 are generally considered stable, though each case must be considered independently.[38]

Osseoperception

One of the peculiarities of osseointegrated prostheses is that mechanical events at the prosthesis (e.g. touch) are transferred as vibrations through the bone.[42] This "osseoperception" means that the prosthesis user regains a more accurate sense of how the prosthesis is interacting with the world. Users of bone-anchored lower limb prostheses report, for example, that they can tell which type of soil they are walking on due to osseoperception.[43]

Recent research on users of bone-anchored upper and lower limb prostheses showed that this osseoperception is not only mediated by mechanoreceptors but also by auditory receptors.[44][45] This means that, rather than just feeling mechanical influences on the device, users also hear the movements of their prosthesis. This joint mechanical and auditory sensory perception is likely responsible for the improved environment perception of users of osseointegrated prostheses compared to traditional socket suspended devices. It is not clear, however, to what extent this implicit sensory feedback actually influences prosthesis users in everyday life.[46]

Applications

  • Prosthetic Implants (e.g.
    Dental Implants
    ) are fields of application
  • Retention of a
    orbital prosthesis
    ), or nose (nose prosthesis)
  • Bone anchored limb prostheses[47]
  • Bone anchored hearing conduction amplification (
    bone anchored hearing aid
    )
  • Eyeborg perceive color through sound waves (sound conduction through bone)
  • Knee and Hip replacement

See also

References

  1. ]
  2. ^ .
  3. ^ .
  4. ^ a b c d Bothe, RT; Beaton, KE; Davenport, HA (1940). "Reaction of bone to multiple metallic implants". Surg Gynecol Obstet. 71: 598–602.
  5. ^
    PMID 14824196
    .
  6. .
  7. ]
  8. ]
  9. ]
  10. ^ a b c Close to the Edge - Brånemark and the Development of Osseointegration, edited by Elaine McClarence, Quintessence 2003.
  11. PMID 26145721
    .
  12. ^ "Veteran amputees to undergo first ever prosthetic implants | KSL.com". www.ksl.com. Retrieved 2015-12-04.
  13. ^ "Osseointegration for Amputees: Past, Present and Future: Basic Science, Innovations in Surgical Technique, Implant Design and Rehabilitation Strategies". scholar.google.com. Retrieved 2023-04-27.
  14. PMID 30445157
    .
  15. .
  16. .
  17. .
  18. .
  19. .
  20. .
  21. ^ Zarb, George A.; Albrektsson, Tomas (1991). "Osseointegration: A requiem for the periodontal ligament?". International Journal of Periodontology and Restorative Dentistry (11): 88–91.
  22. ^ Edge MJ. Surgical placement guide for use with osseointegrated implants. J Prosthet Dent. 1987;57:719–22.
  23. ^ "Implant Surgical Guides: State of the Art". HammasOskari. Retrieved 2019-11-06.
  24. ^ Engelman MJ, Sorensen JA, Moy P. Optimum placement of osseointegrated implants. J Prosthet Dent. 1988;59:467–73.
  25. .
  26. ^ .
  27. .
  28. .
  29. .
  30. .
  31. .
  32. .
  33. .
  34. ^ Biomet Orthopedics, Regenerex® Porous Titanium Construct, http://www.biomet.com/orthopedics/productDetail.cfm?category=2&product=231
  35. ^ Zimmer Orthopedics, Trabeluar Metal Technology, http://www.zimmer.com/ctl?template=CP&op=global&action=1&id=33 Archived 2011-07-18 at the Wayback Machine
  36. ^ Zimmer Cancellous-Structured Titanium Porous Coating, http://www.zimmer.com/ctl?op=global&action=1&id=7876&template=MP Archived 2011-07-18 at the Wayback Machine
  37. ^ Osseointegration with Titanium Foam in Rabbit Femur, YouTube: https://www.youtube.com/watch?v=hdscnna5r1Q
  38. ^ a b c d Implant Dentistry - A Rapidly Evolving Practice. 2011. pp. 111–126.
  39. PMID 27141160
    .
  40. ^ "Methods Used to Assess Implant Stability: Current Status" (PDF). International Journal of Oral and Maxillofacial Implants. 22: 742–754. 2007.
  41. PMID 9258729
    .
  42. .
  43. .
  44. .
  45. ^ "Hearing and touch mediate sensations via osseointegrated prostheses". www.eurekalert.org. Retrieved 2019-04-10.
  46. S2CID 5781724
    .
  47. .

Further reading

External links